IGCSE ยท Class 10
Gas Collection over Water Lab
Collect hydrogen, oxygen, and carbon dioxide by water displacement and compare suitability based on solubility. To collect gases over water and decide when the method gives a reliable gas sample.
Aim
To collect gases over water and decide when the method gives a reliable gas sample.
Theory
A gas that is insoluble or only slightly soluble in water can displace water from an inverted gas jar. Highly soluble gases give low collection volumes and contaminated samples.
Materials
- Flask with thistle funnel and two-hole stopper
- Delivery tube
- Water trough with beehive shelf
- Gas jar
- Reagents to generate hydrogen, oxygen, and carbon dioxide
Procedure
- Fill the gas jar with water and invert it on the beehive shelf in the trough.
- Connect the delivery tube without air gaps.
- Generate the selected gas slowly.
- Record the collected volume and note any solubility loss.
Observations
- Hydrogen: The gas volume rises quickly and the water level falls evenly. Hydrogen is almost insoluble in water, so water displacement gives a useful sample.
- Oxygen: A steady volume of oxygen collects with little loss. Oxygen is only slightly soluble, so the collected volume remains close to the generated amount.
- Carbon dioxide: The collected volume is lower than expected and the water becomes weakly acidic. Carbon dioxide dissolves to form carbonic acid, so water displacement is less accurate.
Result
Hydrogen and oxygen collect well over water; carbon dioxide shows lower collected volume because it dissolves partly in water.
Safety
Use small simulated gas volumes. In a real lab, keep hydrogen away from flames and do not seal a gas generator completely.
Checkpoint question
Why is ammonia not collected over water in standard school gas tests?