BSc Organic ยท Chromatographic Monitoring
TLC Monitoring of Organic Reaction Progress
Spot starting material, reaction mixture, and product standards on TLC plates, calculate Rf values, and decide when the reaction is complete.
Theory
Thin-layer chromatography separates compounds by polarity and adsorption to silica. Rf equals distance travelled by spot divided by distance travelled by solvent front. Reaction completion is inferred when starting material disappears.
Apparatus
- Silica TLC plate
- Capillary spotters
- Developing chamber
- UV lamp
- Reaction aliquots
Observations
- Starting material lane: A single starting-material spot appears at Rf 0.62. Rf = 3.1 cm / 5.0 cm = 0.62. This lane establishes the starting-material reference.
- 10 min reaction: Both starting-material and product spots are visible. Product Rf = 1.8 / 5.0 = 0.36; SM spot remains at 0.62. Two spots show the reaction is incomplete.
- 25 min reaction: Product spot becomes intense and the starting-material spot is faint. Relative product intensity is about 72% of total spot area. The reaction is near completion but should be checked again.
- 40 min reaction: Only the product spot remains under UV visualization. No detectable SM spot at Rf 0.62; product Rf remains 0.36. Disappearance of starting material supports stopping the reaction.
Calculation
Rf = spot distance / solvent front distance. Compare reaction mixture spots with starting-material and product standards.
Safety
Use volatile eluents in a hood, cap the chamber, and avoid looking directly into UV light.